홈 / 제품소개 / 일렉트로 포레이터(BTX) / ECM 399
ECM399
Economical electroporation system for gram negative bacteria and yeast applications
The ECM 399 is an economical electroporation system for gram negative bacteria and yeast applications. Ideal for research and academic labs.
ECM 399 GENERATOR
The ECM 399 is an exponential decay wave electroporaton generator specifically designed to deliver the field strengths and pulse lengths required for the simple transformation of bacteria and yeast cells. In low voltage mode the ECM 399 has a limited capability for transfecting some mammalian cell lines.
The ECM 399 is ideal for basic transformation in research and academic environments.
The ECM 399 is intended For Research Use Only. Not for use in diagnostic, pre-clinical, or clinical procedures.
FEATURES
Highest transformation efficiencies of basic bacteria and yeast strains
Easy to operate
Cost effective
Compact in size and portable
Available as complete system with cuvettes and cuvette rack
Applications
Basic bacteria and yeast transformation
Mammalian transfection (limited, in low voltage mode)
INCLUDED ITEMS
Item # Product Included Items
45-0000
ECM 399 Electroporation System, Complete, for Cuvettes
ECM 399 Generator, PEP, Cuvettes 1 mm, 2 mm, 4 mm, pkg. of 30 (10 each) and Cuvette Rack 660
45-0050
ECM 399 Generator Only
ECM 399 Generator only
SPECIFICATIONS FOR THE ECM 399 GENERATOR
Display Type : 16-character liquid crystal LCD backlit
Power Source Voltage : 100 to 240 VAC, 50 to 60 Hz, CAT I
Power
Fusing : 2.5 A, T rating 250 V
Environmental Characteristics
Intended Use : Indoor use only
Operating Temperature : 10°C to 40°C
Cooling : Convection through metal case
Relative Humidity : 60%
Pollution Degree : Not to be operated in conductive pollutants atmosphere
Altitude : 2,000 m (operating)
Mechanical Characteristics
Footprint : 9.1" x 7.7" x 4.3" (W x D x H)
Weight : 7.0 lb (3.2 kg)
Controls : Single rotary knob with push button toggle to set parameters, On/Off power and Start switches
STANDARD CAPABILITIES
Operational Status : Internal self test upon start-up
Interface : Digital User Interface
Input : 110 V / 220 V Universal
Charge Time : 5 sec maximum (without delay)
Voltage Range : LV Mode: 2 - 500 V / 2 V resolution; HV Mode: 10 - 2,500 V / 10 V resolution
Capacitance : LV Mode: 1,050 µF fixed; HV Mode: 36 µF fixed
Resistance : LV Mode: 150 ohm fixed, HV Mode: 150 ohm fixed
Maximum Voltage Output : 2,500 Volts Peak
Maximum Pulse Length : 125 ms at 500 V peak or 5 ms at 2,500 V peak
Safety : Generator short circuit proof